논문집

원문다운로드
논문명 Bass trap의 저주파수 대역 흡음성능 평가/Evaluation of Sound Absorption Performance of Low -frequency Band of Bass Trap/학술섹션 1-1 : 건축음환경
저자명 정아영(Jeong, A-Yeong) ; 김경우(Kim, Kyoung-Woo) ; 신혜경(Shin, Hye-Kyung) ; 양관섭(Yang, Kwang-Seop)
발행사 한국건축친환경설비학회
수록사항 추계학술발표대회  , 2017
페이지 시작페이지(57) 총페이지(2)
주제분류 환경및설비
주제어 베이스트랩 ; 흡음계수 ; 중량충격음 Bass Trap ; Sound Absorption Coefficient ; Heavy-Weight Impact Sound
요약2 The sound absorption performance of the low-frequency band of the Bass trap was measured, prior to applying the Bass trap to heavy-weight impact sound reduction. The measurement took place in the reverberation room and four bass traps were used. There were two cases of installation when mounting on the floor and at the corner. When mounting on the floor, the NRC value is 1.20, and mounting at the corner, it shows 1.35. Especially, when mounting at the corner, the sound absorption coefficient was 0.09 ~ 0.31 higher at 50Hz ~ 250Hz which is the low-frequency band, and there was no difference in the high-frequency band above 1.25 kHz. In addition, It is shown that the sound absorption coefficient of 0.4 ~ 1.06 in the 63Hz ~ 125Hz band, which is the frequency band for determining the heavy-weight impact sound value, and it is necessary to further study how such low-frequency sound absorption performance can reduce the heavy-weight impact sound.