주제어 창 입면분할 유형 ; 삼중유리 창 ; 열관류율 ; 시뮬레이션 Window Split Type ; Triple Glazing Window ; U-factor ; Simulation
요약2 Thermal performance could be affected by the window split types that the glazing and frame area of each type are various. Therefore, the purpose of this study was to analyze the impact on the thermal performance of the triple glazing windows according to the various window split types. The simulation program of Window/Therm v.6.3 was used to evaluate four different split types of a window model.