논문명 |
공동주택의 실내외 미세먼지 측정을 통한 대기 중 미세먼지의 실내 영향도 평가 기초연구/Preliminary study to assess the effect of outdoor particle on indoor air quality by measuring particle indoor/outdoor concentration in a residential building/1-2 : 공기환경 |
저자명 |
이정호(Lee, Jung-Ho) ; 강동화(Kang, Dong Hwa) ; 최동희(Choi, Dong Hee) |
발행사 |
한국건축친환경설비학회 |
수록사항 |
추계학술발표대회
,
2015
|
페이지 |
시작페이지(63) 총페이지(2)
|
주제분류 |
환경및설비
|
주제어 |
주거건물 ; 실내 미세먼지 ; 실외 미세먼지 ; 침투 ; 실내공기질 Residential Building ; Indoor Particulate Matter ; Outdoor Particulate Matter ; Penetration ; Indoor Air Quality
|
요약2 |
The objective of this study was to assess the effect of outdoor particle concentration on indoor environment in a residential building. The simultaneous measurements of outdoor and indoor particle concentration were carried out in a residential housing unit both when the unit was occupied and unoccupied. The results showed that the I/O (indoor/outdoor) ratio in smaller size particles between 0.3-1.0 μm showed higher value than that in larger size particles, indicating that outdoor air pollution, in particular, could contribute to an increase of indoor particulate in those particle sizes. |
소장처 |
한국건축친환경설비학회 |