논문집

원문다운로드
논문명 부산광역시 공동주택의 방위별 로이유리 최적 저방사 코팅위치 선정에 관한 연구/A Study on the Selection of Optimal Position of Low-Emissivity Coating of Low-E Glass in Apartment Housing to Wall Orientation in Busan
저자명 박환출 ; 이지은 ; 박헌준 ; 이정재
발행사 한국건축친환경설비학회
수록사항 추계학술발표대회  , 2013
페이지 시작페이지(158) 총페이지(4)
주제분류 환경및설비
주제어 공동주택 ; 로이유리 ; 설정실온 ; 방위 ; 냉난방부하 ; 트랜시스 ; Apartment Housing ; Low-E glass ; Set-Point Temperature ; Orientation ; Cooling and Heating Load ; TRNSYS
요약2 This paper suggested optimal position of low-emissivity coating according to wall orientation in apartment housing by analyzing thermal performance. Every orientation except for main orientation was fixed to double glass. And the main orientation glass was changed to Low-E glass which was coated to outside or inside and double glass. The results of simulation, when it applied inside coating glass, it showed the best results about all orientation in the energy saving aspect. It is considered that thermal performance is the best in case of inside coating, regardless of main orientation.
소장처 한국건축친환경설비학회