논문집

원문다운로드
논문명 단열재 두께와 창호의 침기량에 따른 실 부하의 변화에 관한 연구/하이새시와 알루미늄 창호에 대하여/A Study on the Variation of Indoor Heating and Cooling load according to Insulation thickness and Infiltration Rate (Synthetic resins sash and Aluminum sash)/1-2. 열환경 및 성능
저자명 최정민 ; 조성우
발행사 한국건축친환경설비학회
수록사항 춘계학술발표대회  , 2011
페이지 시작페이지(117) 총페이지(4)
주제분류 환경및설비
주제어 침기량 ; 단열재두께 ; 현열부하 ; Infiltration Rate ; insulation Thickness ; Sensible Heat Load
요약2 The infiltration through window is caused by the pressure difference between indoor and outdoor. As the infiltration load is occurring during life cycle of buildings, the heat loss of infiltration is continuing. This study is surveyed compensating effect between insulation thickness and infiltration rate of buildings. The compensating effect is affected by tightness of window and outdoor velocity. The compensating effect of heating and cooling load in this study is 3.3 % in synthetic resins sash and 2.8% in aluminum sash respectively.
소장처 한국건축친환경설비학회