요약2 |
A study of building energy performance evaluation indicator to change from component standard to performance standard. This study is focused on analysis of the heat loss coefficient using dynamic heat load simulation according to change climate. First, The proposition of new heat loss coefficient that considered characteristic of climate. This study findings are as follows: When the same total heating and cooling load, Incheon 1.01, Gwangju 1.21, Ulsan 1.30 and Mokpo 1.31 have higher heat loss coefficient than The base of Seoul |