논문명 소형 공동주택의 기밀성능 취약부위 도출 및 개선효과 비교/Improvement of Poor Air Tightness Performance in Existing Small Apartments
저자명 박정하(Park, Jung-Ha) ; 이병희(Lee, Byung-Hee) ; 김길태(Kim, Gil-Tae) ; 김선동(Kim, Sun-Dong)
발행사 한국건축친환경설비학회
수록사항 한국건축친환경설비학회 논문집  , Vol.16 No.5
페이지 시작페이지(374) 총페이지(11)
ISSN 1976-6483
주제분류 환경및설비
주제어 소형 공동주택; 기밀성능; 감압법 Small Apartment; Air tightness Performance; Depressurization method
요약2 According to carbon neutral strategy, zero energy building design is mandatory for new residential buildings from 2025 in Korea. Air tightness performance of apartment is one of the main factor to reduce building energy consumption. This paper presents to improve the air tightness performance of existing small apartment that greatly affects the building energy use. A field survey was conducted on poor parts of air tightness performance in small apartments, and the air tightness level was measured using a blower door. After improving poor air tightness part of small apartment such as windows and masonry wall around air duct (AD) or pipe duct (PD), air tightness performance was measured again and these results compared. The result are summarized as follows ; (1) According to measuring data of air tightness from 2016 to 2019, the airtightness performance of apartments averaged about 3.17 h-1 at 50 Pa, and 78% of apartments with a measuring result of 4.0 h-1 or higher are small apartments. (2) Poor parts of airtightness performance are window and frames, masonry wall around AD or PD, and pipe connected kitchen exhaust fan in a small apartment. With effect of improving the poor air tightness performance, the air tightness level of existing small apartment (16 m2 ) was deceased from 4.55 h-1 to 3 h-1.