논문명 블로워 도어 테스트 결과를 이용한 아파트의 자연상태 침기량(ACH natural) 산출에 관한 연구/Study on Estimation of Infiltration Rate (ACH natural) using Blower Door Test Results
저자명 문정현(Mun, Jung-Hyon) ; 이종익(Lee, Jong-Ik) ; 김민성(Kim, Min-Sung)
발행사 한국건축친환경설비학회
수록사항 한국건축친환경설비학회 논문집  , Vol.14 No.6
페이지 시작페이지(687) 총페이지(12)
ISSN 1976-6483
주제분류 환경및설비
주제어 블로워도어테스트; 침기; 유체계수; 압력지수; 균열법 Blower door test; Infiltration; Flow coefficient; Pressure exponent; Crack method
요약2 One of primary factor to generate heating and cooling load in apartment houses is infiltration. However, it has not been established well how to evaluate infiltration rates in apartment houses yet in Korea. The existing method is to measure air change per hour at 50 Pa (ACH50) of a house and divide it by the leakage-infiltration ratio, N which has usually been used as 20 in Korea. In this study, another analysis method to evaluate infiltration paths and rate of na apartment house is adopted to find infiltration rate of apartment houses. A series of blower door test were performed in two apartment houses to investigate infiltration paths and to measure an infiltration rate through the paths. Using the blower door test data, the flow coefficient and pressure exponent of each infiltration path were extracted. The values were used as input data of a building energy simulation program, EnergyPlus to calculated natural air change per hour value (ACHn) of two houses. The calculated ACHn values were significantly different from those calculated using the existing method. It is necessary to investigate a proper leakage-infiltration ratio, N for Korea. The method suggested in this study can be used to find it.
소장처 한국건축친환경설비학회