논문집

원문다운로드
논문명 복수센서를 이용한 외단열 건축물의 외피 열관류율 성능 현장 측정 연구/A Study on Site Measurement of the U-value of Building Envelope with Exterior Insulation Finish System using Multiple Sensors
저자명 노상태(No, Sang-Tae)
발행사 한국건축친환경설비학회
수록사항 한국건축친환경설비학회 논문집  , Vol.11 No.1
페이지 시작페이지(58) 총페이지(7)
ISSN 1976-6483
주제분류 환경및설비
주제어 열관류율 ; 외단열 시스템 ; 단열성능 ; 현장 측정 ; 열류센서 U-value ; Exterior insulation finish system ; Insulation Performance ; In-situ measurement ; Heat Flow Sensor
요약2 Ministry of Transportation has strengthened the insulation performance criteria. The enhanced thermal performance and energy savings in the building structure are important. A field thermal testing method with the heat flow measurement sensor is unique for the current assessment of the existing building wall thermal performance. This study examined the differences between measured U-value and conventional calculated U-value(designed value) by attaching the different sensors in the same area using multiple heat flow sensor. Every cases are shown to same patterns on each heat flow and U-value graph, but U-values with regard to various sensors have been shown some differences to designed values.
소장처 한국건축친환경설비학회