논문집

원문다운로드
논문명 공동주택의 준공 전후 측정 시점에 따른 기밀성능 비교/A Comparison of Airtightness in Apartment Buildings before and after Completion
저자명 지경환(Ji, Kyung-Hwan) ; 신현국(Shin, Hyun-Kook) ; 조재훈(Jo, Jae-Hun)
발행사 한국건축친환경설비학회
수록사항 한국건축친환경설비학회 논문집  , Vol.10 No.1
페이지 시작페이지(55) 총페이지(6)
ISSN 1976-6483
주제분류 환경및설비
주제어 ISO 9972 ; 측정 준비 ; 측정 표준 ; 기밀성능 ; 팬가압법 ISO 9972 ; Preparation ; Measurement standard ; Airtightness ; Fan presurrization method
요약2 The building airtightness level can be only known by the measurement. The preparations for measuring building airtightness are implemented before or after completion of construction. The preparation section(5.2) in ISO 9972 describes the preparation details before measurement with three types of methods(Method A, Method B, Method C) according to the purpose of measuring a test building. Method A and Method C are the ways of measuring airtightness of a building in use after completion. They are distinguished by the conditions of exhaust fans connected to outside(sealed or damper closed). According to the Method B, all openings connected to outside in a test building are required to be sealed to measure airtightness of the building envelope before completion. In this study, airtightness was measured with 10 units which have 2 unit-plan types in apartment building. The building airtightness were compared according to Method A, B, C. The result of airtightness measurement shows high-performanced airtightness in order as Method C, A, B. The interior furnishings and the conditions of exhaust fans affect the building airtightness levels.
소장처 한국건축친환경설비학회