논문명 부산지역 사무소 건물의 Low-E 유리 최적 코팅위치 선정에 관한 연구/A Study on the Selection of Optimal Coating Position of Low-E Glass at Office Building in Busan
저자명 박종언(Park, Jong-Eon) ; 박헌준(Park, Heon-jun) ; 이정재(Yee, Jurng-Jae)
발행사 한국건축친환경설비학회
수록사항 한국건축친환경설비학회 논문집  , Vol.9 No.4
페이지 시작페이지(298) 총페이지(6)
ISSN 1976-6483
주제분류 환경및설비
주제어 Low-E 유리 ; 설문조사 ; 스케줄 ; 밀도 ; 최적 코팅위치 Low-E glass ; Survey ; Schedule ; Density ; Optimal Coating Position
요약2 The study of this paper is to analysis of property which irradiated internal heat gain of office in Busan. Base on this, It was selected Low-E glass optimal coating position for office in Busan. Internal heat gain property which surveyed for office in Busan was occupancy density 8.63W/㎡, lighting density 10.67W/㎡, computer density 6.04W/㎡, monitor 3.01W/㎡, copier & printer 1.68W/㎡, fax machine 0.08W/㎡. Analysis results were as follows of annual cooling & heating load of effective. 2# coating Low-E glass was result value of 614,753.05kWh/yr from building position of west. 3# coating Low-E glass was result value of 686,046.87kWh/yr from building position of north. The office in Busan was effective of 2# coating Low-E glass.