논문집

원문다운로드
논문명 노후 철도 방음벽의 성능에 관한 연구/Research on the Performance of Deterioration Railroad Noise Barrier Wall
저자명 주문기(Joo, Mun-Ki) ; 고효인(Ko Hyo-In) ; 홍지영(Hong Ji-Young) ; 오양기(Oh Yang-Ki)
발행사 한국건축친환경설비학회
수록사항 한국건축친환경설비학회 논문집  , Vol.9 No.3
페이지 시작페이지(242) 총페이지(5)
ISSN 1976-6483
주제분류 환경및설비
주제어 철도 ; 방음벽 ; 관리규정 ; 노후화 Rail road ; Noise barrier wall ; Management regulation ; Deterioration
요약2 In recently, numbers of civil appeal about railroad noise are growing due to the deterioration railroad noise barrier walls. The regulation of sound barrier wall used sound absorption coefficient of sound proof panels must apply the average of sound absorption coefficient in four frequency ranges (250,500,1000,2000㎐). In the measurement , the regulation of sound absorption coefficient is satisfactory when the average value of sound absorption coefficient is over 0.7. However after installation of noise barrier wall, it isn't know whether the performances of noise barrier walls are good or bad because of being not a management regulation of noise barrier wall. So in this study, the measurements of sound absorption coefficient and investigate on the present condition of noise barrier walls were carried out in the field and laboratory. As the results, the number of problem on the noise barrier wall were found out. According to the deterioration, a damaged part and bending problem and crack and deterioration of sound absorption material has appeared in the noise barrier wall. Particularly sound absorption coefficient of over 1㎑ frequency ranges were measured 0.8-0.52. It seemed to be clogged with the dust in the absorption material. So it is expected that the management regulation of railroad noise barrier wall is needed.
소장처 한국건축친환경설비학회