논문집

원문다운로드
논문명 창호 크기와 성능이 열관류율에 미치는 영향에 대한 연구/A Study on the Influence of the U-value According to the Window Size and Performance
저자명 장향인 ; 최원기 ; 최경석 ; 엄재용 ; 이현수 ; 서승직
발행사 한국건축친환경설비학회
수록사항 한국건축친환경설비학회 논문집  , v.8 n.1
페이지 시작페이지(14) 총페이지(7)
ISSN 1976-6483
주제분류 환경및설비
주제어 창호크기 ; 창호성능 ; 열관류율 ; Window Size ; Window Performance ; U Value
요약2 Windows of the buildings will be installed in a variety of sizes and shapes, but 2m × 2m sized windows(specimen) are evaluating U value by the KS F 2278, so there is a difference between windows that are applied to the actual building and specimen. In this paper, it is evaluated on U value by the effects of changes in size of windows, correlation was derived. The following conclusions were derived. 1) Depending on the type of spacer average U value difference is approximately 0.06 W/㎡·K. 2) 0.005 W/m·K increase in linear U value, U value is increased approximately 0.0094 W/㎡·K. 3) In the same conditions of the frame, as excellent U value of glazing, U value of windows bigger changes according to the window size changes. Later, the U value change analysis according to the size will be performed for various types of windows in order to provide a reasonable calculation criteria, so additional studies should be performed.
소장처 한국건축친환경설비학회