논문명 보일러 대수제어에 따른 사무소건물 난방에너지 절감에 대한 연구/The Heating Energy Saving Effect by Operating Number Control of Boilers in Office Building
저자명 윤갑천 ; 박두용 ; 윤경 ; 김영민 ; 김영섭 ; 김강수
발행사 한국건축친환경설비학회
수록사항 한국건축친환경설비학회 논문집  , v.7 n.2
페이지 시작페이지(120) 총페이지(6)
ISSN 1976-6483
주제분류 환경및설비
주제어 보일러 ; 대수제어 ; 사무소 ; 난방에너지 ; HW Boiler ; Operating number control ; Office ; Heating energy
요약2 We proposed the operating number control of hot water boiler to save the heating energy consumption in office building. First, we split the existing boiler into two same capacity(500KW). As a result, the heating energy saving rate was 21%. And, we split the existing boiler into two capacity of 700KW and 300KW according to the heating load. In this case, the heating energy saving rate was 33%. These results presents the higher saving rates of heating energy consumption about 11% than that of the case of improving the existing boiler efficiency from 80% to 90%. Therefore, it can be said that the operating number control is more efficient way to reduce heating energy consumption than the improvement of existing boiler efficiency.