보일러 대수제어에 따른 사무소건물 난방에너지 절감에 대한 연구/The Heating Energy Saving Effect by Operating Number Control of Boilers in Office Building |
저자명 |
윤갑천 ; 박두용 ; 윤경 ; 김영민 ; 김영섭 ; 김강수 |
발행사 |
한국건축친환경설비학회 |
수록사항 |
한국건축친환경설비학회 논문집
,
v.7 n.2
|
페이지 |
시작페이지(120) 총페이지(6)
|
ISSN |
1976-6483 |
주제분류 |
환경및설비
|
주제어 |
보일러 ; 대수제어 ; 사무소 ; 난방에너지 ; HW Boiler ; Operating number control ; Office ; Heating energy
|
요약2 |
We proposed the operating number control of hot water boiler to save the heating energy consumption in office building. First, we split the existing boiler into two same capacity(500KW). As a result, the heating energy saving rate was 21%. And, we split the existing boiler into two capacity of 700KW and 300KW according to the heating load. In this case, the heating energy saving rate was 33%. These results presents the higher saving rates of heating energy consumption about 11% than that of the case of improving the existing boiler efficiency from 80% to 90%. Therefore, it can be said that the operating number control is more efficient way to reduce heating energy consumption than the improvement of existing boiler efficiency. |