논문집

원문다운로드
논문명 오피스 건물의 창면적비와 일사열취득계수에 따른 최적의 창호 구성에 관한 기초 연구/A Fundamental Study on the Optimal Window Applications According to the Window Ratio and SHGC in Office Buildings
저자명 윤용상 ; 윤재훈 ; 최원기 ; 권영철
발행사 한국건축친환경설비학회
수록사항 한국건축친환경설비학회 논문집  , v.6 n.1
페이지 시작페이지(38) 총페이지(8)
ISSN 1976-6483
주제분류 환경및설비
주제어 창면적비 ; 일사열취득계수 ; 가시광선 투과율 ; LSG(일사열취득 대비 가시광선 투과율) ; 에너지 절약 ; Window to Wall Ratio ; SHGC ; Visible Light Transmission ; LSG(Light to Solar Gain) ; Energy Saving
요약2 The office buildings with the curtain wall structure are weak in the cooling load, because of the high frequency of usage and the high interior gains during a day. Controlling Window to Wall Ratio and applying low U-factor windows are used to improve this, but they have the limitation of the improvement. In this study, a building energy simulation was conducted. And the influence on the energy performance was analyzed according to Window to Wall Ratio(WWR), Visible light Transmittance(VLT), Solar Heat Gain Coefficient(SHGC) and U-value. The results of this study are as follows; 1) WWR can be an independent index of energy performance of the office buildings with dimming control system. 2) As SHGC of glazing is higher, cooing energy is increased, heating energy is decrease. And total energy is increased. That is the change of SHGC more influence on cooling energy than heating energy. 3) As SHGC of glazing is lower, the turning point of cooling and total energy in a high WWR. And the energy reverse is occurred when WWR is so low. That is increase of lighting energy is higher than decrease of cooling energy, when WWR is so low. 4) The planning for energy saving of office buildings with dimming control system is considered SHGC and VLT first and WWR after.
소장처 한국건축친환경설비학회