논문명 현장측정에 의한 데이터센터 서버실의 냉각시스템 분석/Analysis of Cooling System for Server Room through Field Measurement in Internet Data Center
저자명 정용호
발행사 한국건축친환경설비학회
수록사항 한국건축친환경설비학회 논문집  , v.6 n.1
페이지 시작페이지(9) 총페이지(8)
ISSN 1976-6483
주제분류 환경및설비
주제어 데이터 센터 ; 에너지 비용 ; 밀폐형 쿨링시스템 ; 재순환공기 ; 냉복도 ; Data center ; Energy cost ; Cold aisle containment system ; Re-circulation air ; Cold aisle
요약2 Energy Cost has been rapidly increased with the internal heat gain of data center to keep the temperature condition. But the cooling units for server systems are fully operated to satisfy the indoor temperature condition, it results in the excessive energy consumption. In this study, various cooling systems were studied for data center and cold aisle containment system was proved to be the best solution for server cooling system. Because it protects the cooling zone from the hot aisle space. Effective cooling and prohibition of recirculation air from hot aisle was possible by the cold aisle containment system.