논문명 인접건물에 의한 파사드일체형 BIPV모듈의 음영영향 평가연구/A Study on the Shading Effect of Facade Integrated BIPV Module System Depending on the Configuration of Adjacent Building Shape.
저자명 안영섭 ; 이정환 ; 윤종호
발행사 한국건축친환경설비학회
수록사항 한국건축친환경설비학회 논문집  , v.1 n.2
페이지 시작페이지(28) 총페이지(6)
주제분류 환경및설비
주제어 건물일체형 태양광발전(BIPV) ; 인접건물 ; 음영효과 ; 음영면적비 ; Building Intergrated Photovoltaic(BIPV) ; Adjacent Building ; Shading Effect ; Shading Area Ratio
요약1 본 연구에서는 상업용 건물 파사드(facade)에 적용된 PV모듈을 대상으로 인접건물에 의한 음영의 영향이 발전성능에 미치는 효과를 예측평가 함으로서 건축실무자들을 위한 BIPV용 기초 설계자료를 제시하는 데 목적이 있다.
요약2 Technologies generating electricity using photovoltaic(PV) resource have a variety of applications without specialized maintenance, environmental pollution triggered, and corrosion of materials. Among one of the various technologies is the development and popularization of building integrated photovoltaic system (BIPV), especially replacing PV with external finishing materials that is being progressed throughout the world. Building integrated photovoltaic system(BIPV) is composed by PV modules which used as building exterior component material. And it takes high economic effects and added value to the building itself. BIVP system do generates electricity. And it has the functions which are outer wall, roof, window, fasade, shading material etc. When the high cost building exterior material is to be replaced by BIPV module, BIPV has more economical efficiency. The existing solar generating system need the space and the structural elements for install, but BIPV need no space and structural elements.Somewhat, The architectural structure, construction, raw, safety, endurance and etc. must be examined to building integrated element as BIPV. And environmental factor such as thermal performance, natural lighting performance, and shield the noise performance must be evaluated extensively.This study evaluates the shading effect of exterior type BIPV module. The evaluation factor was defined as area, building height, building width, building azimuth. Result shows the relationship between shading and generation when the PV module was used as building exterior elements.
소장처 한국건축친환경설비학회